Classification: | Holter ECG |
---|---|
Type: | ECG |
Certification: | ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model: CCO-EB100
Function
Feature
1)USB high-speed transmission.
2)Sync collection of 12-lead ECG, BP and SpO2 data for 24 h at least.
3)Comprehensive analysis of ECG and BP.
ECG
1)Display and print ECG waveform at any time during collection.
2)Multi - lead overlay analysis, any lead can be selected for analyzing, more accurate to search QRS wave.
3)Histogram analysis function, interval, interval ratio, voltage, QRS width, QRS area and HR histogram can be selected for analyzing.
4)Scatter plot (including density and mixed scatter plot) analysis function.
5)Atrial fibrillation analysis function adopts the mode of combining time scatter plot and Lorenz scatter plot, intuitive to display the location of atrial fibrillation event, convenient to positioning for diagnosis.
6)With the functions of arrhythmia, bradycardia and ST-T analysis.
NIBP
1)With the functions of 24 h automatic cycling BP measurement and setting measurement interval.
2)BP data review and report print functions.
3)Measurement of systolic pressure, diastolic pressure and mean pressure.
SpO2
1)Measurement of SpO2 and PR.
2)SpO2 trend chart review and print functions.
Performance
ECG
Lead: standard 12-lead
Record time: ≥ 24 h
Dynamic input range: 10 mV
Input impedance: ≥ 10 M
CMRR: ≥ 60 dB
Gain accuracy: ≤ 10 %
Gain stability: ≤ 3 %
System noise: ≤ 50 μV
Multichannel crosstalk: ≤ 0.2 mV
Frequency response: 0.05 Hz ~ 40 Hz (+3 dB ~ -3 dB)
Minimum detection signal: minimum amplitude: 50 μV
NIBP
Measurement method: Oscillometry
Measurement range: pressure: 0 ~ 297 mmHg
Resolution: pressure: 1 mmHg (0.133 kPa)
Accuracy: static pressure: ± 3 mmHg (± 0.4 kPa)
Error:
Mean deviation: ≤ ± 5mmHg (± 0.67 kPa)
Standard deviation: ≤ 8 mmHg (1.067 kPa)
SpO2
SpO2 measurement range: 0 % ~ 100 %
PR measurement range: 30 bpm ~ 250 bpm
Others
Display mode: 2.4" color LCD
Battery: two AA alkaline batteries
Rated voltage: DC 3 V
Safety class:
Internally powered equipment
ECG: type BF applied part
NIBP: defibrillation - proof type BF applied part
SpO2: type BF applied part
Accessories
NIBP cuff for adult
NIBP extension tube
USB cable
ECG cable
ECG electrode
PC software
Backpack
User Manual
SpO2 probe (optional)
Adult BP cuff for other size (optional)
Physical characteristic
Dimension: 128 (L) × 69 (W) × 36 (H) mm (main unit)
Weight: about 320 g (without battery)
Operating environment:
Relative humidity: 15 % ~ 85 %, non-condensing
Atmospheric pressure: 700 hPa ~ 1060 hPa
Storage environment
Relative humidity: ≤ 95 %
Atmospheric pressure: 500 hPa ~ 1060 hPa
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |