Theory: | Autoclave |
---|---|
Type: | Pressure Steam Sterilization Equipments |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model:CCS-E18/CCS-E23
18L Class B bench-top autoclave sterilizer
European B standard
EN13060 Standard
LCD Display
121ºC/134ºC
Separately Programme for Testing
Double-Lock for safety
Color: bule or gray or green
Build-in Printer
Technical parameters
Model | Voltage/Power | Chamber Size (mm) |
Outside Size (mm) |
Packing Size (mm) |
Net Weight (kg) |
CCS-E18 | 220V/1500W | φ245×350 | 471×586×395 | 660×525×495 | 47.4 |
CCS-E23 | 220V/1700W | φ245×450 | 471×696×395 | 770×530×495 | 53.4 |
Product Function:
1. The main system specially revised according to EN13060 standard with intelligent. Adjusting sterilizing
time and vacuuming time, more accurate control for stable and crashing sterilization effect.
2. New LCD display window, 5 buttons control panel, for convenient and easy operation.
3. Intelligent help system could demonstrate the condition of sterilization automatically.
4. Both printer and USB output, you could choose the way which you like to backup the sterilization records.
The specification on the output is more accurate and detailed.
5. Memory system inside, you could check the sterilization.
6. Adding a new set temperature detecting device. There are two sets separate temperature detecting device
inside. One is for controlling the temperature, the other one is for checking the controlling temperature, it could
prevent if the temperature sensor for controlling temperature disabled or incorrect and bring the incompletely
sterilization. The precision of temperature control developing decuple, it could be precision to 0.1 degree.
7. Adjusting the check mode of vacuuming, adopt higher parse defree pressure sensor, the precision could be
0.001bar, it will collect the temperature or pressure value per 30ns a time during the program. More accurate
value collects for exact analysis and self-checking automatically.
Technical parameters
Model |
Voltage/Power |
mm |
mm |
mm |
kg |
CCS-C18 18L |
220V/1500W |
φ245×360mm |
560X450X400mm |
660X525X495mm |
47kg |
CCS-C23 23L |
220V/1700W |
φ245×470mm |
670X450X400mm |
770X530X495mm |
53kg |
autoclave class b
Features:
1. The newly-designed model with opening water tank on the top, strictly meets the
standard of EN13060, which makes wash and cleaning much more convenient.
2. It adopts European B standard with 3-times pre-vacuum preceding vacuum drying.
Residual humidity is less than 0.2%.
3. Vacuum measurement reaches-0.8bar.It sterilizes and sanitizes miscellaneous packed
or unpacked medical instruments, Whether solid or A-type hollow, whether with
multi-apertures or inset pipes. It efficiently tides air from every hollow area of any hollow
instrument, such as hand-piece, making sure that water steam reaches every corner.
4. Fuzzily computer controlled, digital bright show. The interface is modularized panel
for easy operation.
5. It is installed with BOWIE&DICK which measures the penetration of water steam.
6. Mini printer can be attached to record the process of sterilization.
We CONCERNMED make one-stop shopping hospital medical equipment:
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |