Classification: | Biochemical Apparatus |
---|---|
Type: | Biochemistry Analyzer |
Certification: | ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model:CCL-C180
Technical parameters
Throughput | Constant 180T/h (non-ISE) | |
Theory | Absorption spectrometry, transmission turbidimetry | |
Methodology | End-point,Fixed-time,Kinetic,Ion selective electrode | |
Test according set up, random access | ||
Reaction plate | Contain 81 reaction cuvettes | |
Maximum reaction time | 15 minutes | |
Minimum reaction volume | 150 ul | |
Material of cuvettes | Special UV-transparent optical glass | |
Cuvettes use | Automatically cuvettes washing | |
Optical Unit | ||
Light Source | Halogen-tungsten lamp | |
Photometer | Reversed optics | |
Wavelength | 340nm-900nm wavelength option | |
Absorption | 0-4 Abs | |
Reagent Unit | ||
Reagent plate | 60 reagent positions,support for single and double reagent, reagent completely open | |
Reagent storage temperature | 2~10ºC | |
Reagent bottle | 15ml, 20ml, 30ml, 50ml or 70ml,dead volume is less than 1.0 ml | |
Reagent volume | 20-500 ul, step by 1.0 ul | |
Reagent/Sample Probe | Automatically checked;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Sample Unit | ||
Sample plate | 60 sample positions | |
Sample type | Human (animal) serum,plasma,urine etc. | |
Samples cup | Support one-off micro cups | |
Sample volume | 2-100 ul, step by 0.1 ul | |
Sample/reagent probe | Automatically checked;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Temperature control Unit | ||
Heating method | Direct thermal solid thermostat closed | |
Temperature equilibrium time | <3 minutes | |
Reaction temperature | 37±0.1ºC | |
Temperature fluctuation | ±0.1ºC | |
Operation Unit | ||
Software | WindowsXP,2000 | |
Database | SQL Server | |
Data Storage | Automatic store & copy; No time and volume limit; Lifetime preservation | |
Print format | Can be set up, offer several standard format | |
Calibration mode | Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | |
Quality control methods: | Real time, within day & between day | |
Quality control diagram | L-J,cumulative,twin plot | |
Status display | Real time monitoring of reagent residual volume. Running status of reagent tray, samples tray | |
Adjustment | Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages | |
Setting | Operation permission setting, Item setting, cross pollution setting, cuvette blank setting | |
Others | ||
Water consumption: < 6L/h | Power Supply: AC 220V±22V 50Hz±1Hz | |
Frequency: Maximum 600VA | Dimension:782mm×581mm×545mm | |
Net Weight: 60kg | Accessory: Software |
We CONCERNMED make one-stop shopping hospital medical equipment:
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |