Type: | Anesthesia Machine |
---|---|
Application: | Orthopedic, Abdominal, Ent, Neurosurgery, Microsurgery, Anorectal, Urology, Burns |
Material: | Steel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model:CCO-560B2
Features:
NO | ||
1 | Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant |
2 | Scope of application | Adults & children |
3 | Gas source | O2, N2O: 0.27~0.55MPa |
4 | Flow meter | O2: 0.1~1.0L/min 1.1~10L/min |
5 | O2, N2O linkage and N2O Stopper | When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. |
6 | Flow rate of rapid oxygen supply | 25~75L/min |
7 | Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa |
8 | Vaporizer | It has the function of automatic compensation based onpressure,temperature,and flow rate. The regulation range ofevaporator concentration is 0~5 vol%. Customer can choose one kind of gas container from Halothane, Enflurane, Isoflurane and Sevoflurane. |
9 | Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa |
10 | Respiratory bellows | bellows for adults, bellows for children tidal volume range:0~1500 ml |
Display mode | High-definition 5.7" LCD screen display |
Ventilation mode | IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH |
Ventilation parameters | Tidal volume: 50~1500ml Rate: 2~99bpm SIMV rate: 2 ~ 20bmp I:E: 2:1~1:8 Inspiratory trigger pressure-1.0~2.0 kPa PEEP: 0~2.0 kPa Pressure range: 1.0~6.0 kPa SIGH 1.5 times the inspiratory time |
Parameters for ventilation monitoring | tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate,I/E, peak pressure of airway,pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure |
Monitor of oxygen concentration | (21%~100%) |
Security Alarm System | O2 concentration alarm Upper limit setting range (50%~100%) Low limit setting range (15%~50%) Airway pressure alarm Upper limit setting range 1.0~6.0 kPa Low limit setting range 0.4~2.0 kPa Per-minute ventilation volume alarm Upper limit setting range 3.0~30L/min Low limit setting range 1.0~10L/min Sustained high-pressure alarm: It will give alarm when stress have consistentlybeen higher than 2.5 kPa Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds Power alarm |
Power | AC 220V±10% 50Hz±1Hz (UPS, Storage battery) |
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |