| Customized: | Customized |
|---|---|
| Certification: | CE, ISO13485 |
| Scale: | Large |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model:CCX-M900
· 2 film sizes supported,suitable for almost breast shape
· High end X-ray tube selected with Mo/W target
· ISO rotation center C-arm allows multiple screening positions easily
· Multilevel compression level ensure the comfort and safety of patients
· Stand alone design looks more elegant
· High DQE guarantees high quality images with certain low radiation dose emission
· Film screen style could be easily updated to CR digital mammo with IP board
Technical parameters
| Power input: 5000VA |
| System voltage: 20~35 kV in step 1kv |
| Max.mAs: 630mAs |
| Imported X-ray Tube: Molybdenum Anode Focal spot size: 0.1mm(small)/0.3mm(large) |
| Support ISO-CENTER rotation Rotation range: +180°~ -135° |
| C-arm supports dual side digital LCD display |
| Max. vertical movement range: 580mm±2% |
| Compression plate supports flexible and multi-level smart compression |
| Spatial Resolution: 6 Lp/mm |
| Detector type: Amorphous Silicon Detector |
| Detector size: 24*30cm |
| Acquisition Station compatible with DICOM 3.0 |
| Focal distance : 650mm |
| Added filter: Mo / Rh / AG |
| Added filter Switch: Manual/Automatic |
| Support magnification plate |
| Exposure control: supports manual exposure and automatic exposure |
| Power supply: 220 V~,±10% |
| Power frequency: 50/60Hz±1 Hz |
| Frequency: 100KHz; |
| Tube voltage Range: 20 kV ~ 40 kV |
| Max. Output: 5 kW |
| Max. tube voltage:40kV |
| Max. tube current: 200mA |
| Imported X-ray tube |
| Anode Type: Molybdenum; |
| Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) |
| Permanent filter: 0.5mmBe |
| Max. anode speed: 10000rpm |
| Max. tube voltage: 40kV |
| Max. tube current: 35mA(small)/140mA(Large) |
| Max. tube assembly heat content: 320 KJ |
| C-arm up-down and rotation movement controlled via C-arm control panel |
| Rotation type of C-arm: ISO-CENTER rotation around the examined part |
| Rotation range of C-arm: -135o~180o |
| Distance between focal spot and image reception area:650mm |
| Support magnification plate |
| Local display panel on the both side of the stand can indicate rotation angle of C-arm |
| For safer operation, emergency stop button is located on the top of C-arm |
| Up-down movement : power-driven electrically |
| Compression control: continuous activation by foot |
| Compression mode: flexible and multi-level compression, automatic and manual decompression |
| Compression plate travel range: 5~268mm; |
| Compression force: 0~200N |
| Compression thickness: 5~268mm |
| Detector type: Amorphous Silicon Detector |
| Material: Amorphous Silicon |
| Min. pixel: 85µm |
| Image Matrix Sizes: 2816×3528 pixels |
| Effective Imaging Area: 24cm×30cm |
| Spatial Resolution: 6 lp/mm |
| DQE: 50% (1 Lp/mm) |
| Intel CPU frequency≥2.4GHz,≥ 4 GB Memory, ≥500 GB HDD |
| Medical Display, 1 MP, Brightness 250Cd/m2, Contrast 1000:1 |
| Image Detector Self-check and adjustment |
| Patient Information and Image Management |
| Auto Explore Control |
| Acquisition of Explored Image Information |
| Browsing and Searching of Image |
| Measure the Distance, Angle, Space of Image and Mark The Selected Area |
| Image Process after Acquisition: Black and white reverse, rotate and flip, zoom, local editing, enhancement, filtering noise, copies, abridged, etc |
| DICOM 3.0 Services , supports Print, Store, Query/Retrieve, CDRW, Scheduled Workflow and Patient Information Reconciliation |
| Automatic failure diagnosis, error code and message indication |
| Exposure activation: exposure button |
| Data backup and recovery |
| X-ray Room Equipment | Digital X-ray |
| Flat Panel Detector | |
| Stationary/Mobile/Portable X-ray | |
| Mammography/ C-arm X-ray | |
| Dental X-ray Machine/Sensor | |
| X-ray Accessories | |
| X-ray Protection Series | |
| Others X-ray Related Equipment |


