Model:CCO-D80D
Features:
Physical characteristics:
Main unit: Portable
Dimensions:L320xW205xH410
Weight:9.5kg
Technical specifications
DEFIBRILLATOR
(1)Defibrillator type Manual, Synchronized, Asynchronized,
(2)Out put waveform Biphasic technology
(3)Energy accuracy ∠+1%
(4)Energy selection 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joule (nominal ata resistance of 50)
(5)Charging time Maximum 8 seconds to 360 Joules
(6)Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
Power requirements.
(a)AC Power supply 110V, 60 Hz /220V, 50 Hz
(b)Vehicle Voltage DC 12V
Internal Battery Backup
(1)Battery type Rechargeable lead-acid battery
(2)Charging time Time-Minimum of 4 hours for full charging
(3)Battery charging During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication Red LED
(5)Battery Capacity 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.
Display
-LED Dimensions 7'diagonal {155mm*88mm} which is easily read from a distance.
-Type High resolution true-color graphic LED
-Resolution 480X234
- Provide cardioversion facilities with waveform annotated on the screen
- Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.
- Display prompts, waveform settings, battery status, event summary and fault codes. Energy selected is displayed by push button under the screen.
ECG
ECG lead: , , , AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
Standard parameter & configuration
ECG/ RESP/DEFIBRILLATOR
-Provide audible and visual alarms for heart rate violations, VF and VT.
-Provide a strip printer which annotates waveforms, events, time code
-Have a 5-lead patient cable as an option to a 3-lead cable.
-Supplied with external re-usable paddles and packs of paper rolls for the printer.
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |