• Medical Hospital Surgery Operation Room Mobile ICU Machine
  • Medical Hospital Surgery Operation Room Mobile ICU Machine
  • Medical Hospital Surgery Operation Room Mobile ICU Machine
  • Medical Hospital Surgery Operation Room Mobile ICU Machine
  • Medical Hospital Surgery Operation Room Mobile ICU Machine
  • Medical Hospital Surgery Operation Room Mobile ICU Machine

Medical Hospital Surgery Operation Room Mobile ICU Machine

Material: Steel
Feature: Reusable
Certification: ISO13485
Warrant: 1 Year
Transport Package: Standard Export Package
Specification: optional
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
CCO-A500
Trademark
Comcernmed
Origin
China

Product Description

Medical hospital surgery room Mobile ICU Anesthesia

Model:CCO-A500
Medical Hospital Surgery Operation Room Mobile ICU Machine

Features: 

 

Details:

The ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. It is mainly intended for providing ventilation support to a critically ill patient during the life threatening phase and ensuring the going-through of the dangerous period by the patient and smooth treatment of primary diseases for recovery. Also it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
ALL MANIN UNIT HAS PASS THE CE
The automatic conversion for standby power while AC power outage,
keep working not less than 1 hour
TECHNIQUES SPECIFICATIONS
Physical specifications
Display LED Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot
operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 6~60 times/ min
Oxygen concentration output <50%
minute volume ≥18L
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH
PEEP: 0.1 ~ 1.0 kPa
Ptr: -4 ~ 10 hPa
IMV frequency: 1~12 bpm
I/E Ratio: 1:1.5; 1:2.0; 1:2.5; 1:3.0
Tidal Volume Not less than 50~ 1200ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration
time is 1.5 times of the setting point
Pressure limit range: 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.9 kPa ~ 5.4 kPa;   Upper: 0.5   kPa
  ±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s,
then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the ICU ventilator must be well grounded.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product
is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising
an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.
STANDARD CONFIGURATIONS
QTY NAME
1 set Main unit
1 set Oxygen tube
2 set Silicone Mask
1 pc Power line
2 pcs Threaded pipe
2 pcs Standard Pipe
1 set Oxygen Reducer
1 set Humidifier
1 pc Battery
1 set flow sensor
2 pcs A leather bag ( Blue)
1 set Tools with the machine
1 set User Manual (English Version)
 
We CONCERNMED make one-stop shopping hospital medical equipment:
 
one-stop shopping
hospital medical equipment
x ray room x ray machine
processor
x ray film
cassette
Intensifying screen
lead clothings(lead glove, lead glasses,
lead cap, lead apron, lead collar)
ultrasound b/w 2D ultrasound
2/3/4D color ultrasound
laboratory room chemistry analyzer
hematology analyzer
microplate elisa reader
microplate washer
centrifuge
pipette
water bath
urine analyzer
operation room anesthesia machine
ventilator
operating lamp
operation table
pendant
medical drill and saw
ECG 
patient monitor 
defibrillator
infusion pump 
electrocoagulation
oxygen generator
electric suction device
autoclave sterilizer
ect.


Medical Hospital Surgery Operation Room Mobile ICU Machine
Medical Hospital Surgery Operation Room Mobile ICU Machine
Medical Hospital Surgery Operation Room Mobile ICU Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Terms of Payment
LC, T/T, Western Union, Money Gram