Type: | Syringe Pump |
---|---|
Application: | Orthopedic, Abdominal, Ent, Neurosurgery, Microsurgery, Anorectal, Urology, Burns |
Material: | Plastic |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model: CCO-SPS1
Dual CPU Control System
Visual and Audible Alarm System
Self-testing System
Plug-in and modular design, quick combined
Independent handle design make quick installation anddisassembly.
PBT plastic material for anti-corrosion
Excellent waterproof performance
3.5" Colour Touch screen and key pad ope-ration be freely choosing
Easy operation by UI design
Fast start, eliminate the deviation caused by start delay
Full-range syringes compatibility, compatible for 2ml,5ml,10ml,20ml.30ml.50(60)ml syringes
Various work modes to meet different clinical requirements
Change infusion rate without pause
Intelligent Visual and audible alarm system and dynamic alarm guidance
Flow compensation to avoid error caused by pipeline fatigue
Equipment maintenance cycle alert, Regu-larly alert maintenance to make accuracyand safety of the device
Technical parameters:
Applicable Syringe Size
|
2ml, 5ml, 10ml, 20ml, 30ml, 50/60ml
|
Rate
|
2ml:0.01~60ml/h, 5ml:0.01~150ml/h, 10ml:0.01~300ml/h, 20ml:0.01~600ml/h, 30ml:0.01~900ml/h, 50/60ml:0.01~2200ml/h |
Bolus Rate & Volume
|
2ml:0.01~48ml/h 0.1~0.5ml 5ml:0.01~120ml/h 0.1~1ml 10ml:0.01~240ml/h 0.1~5ml 20ml:0.01~480ml/h 0.1~10ml 30ml:0.01~720ml/h 0.1~10ml 50/60ml:0.01~2200ml/h 0.1~10ml |
FF Rate
|
2ml:0.01~60ml/h, 5ml:0.01~150ml/h, 10ml:0.01~300ml/h, 20ml:0.01~600ml/h, 30ml:0.01~900ml/h, 50/60ml:0.01~2200ml/h |
KVO Rate & Volume
|
Rate: 0.01~5.0ml/h Volume: 2ml:0~0.2ml, 5ml:0~0.2ml, 10ml:0~0.2ml, 20ml:0~0.5ml, 30ml:0~0.5ml, 50/60ml:0~1ml |
Rate Accuracy
|
Within ±2% (after calibration)
|
Occlusion Pressure Levels
|
13 Levels are available
|
Alarms Information
|
Infusion finished, near infusion end, VTBI finished, system stand-by completed, infusion is blocked, syringe falls off, syringe is improperly installed, forgotten operation, low battery, battery empty, abnormal running state, equipment failure, power failure etc. |
Prompts
|
Parameter overrun, infusion begins, AC power has been pulled out, speed overrun |
Power Source
|
Three options for power supply: First: 100~240VAC, 50/60Hz; Second: Inserted Li-battery 11.1V, capacity≥2600mAh, 8 hours backup time at the rate of 5ml/h for a fully charged battery; Third: External DC 15V power supply |
Drug Library
|
Up to 1000 drugs are provided.
|
Dimensions
|
301mm(L)×183mm(W)×82mm(H)
|
INFUSION rate range
|
0.01 to 2200 mL/h, with 0.01ml/h increasement
|
Volume to be infused (VTBI)
|
0.01-9999.99ml (0.01 ml/step)
|
Infusion time
|
99H:59M:59S
|
Purge/Bolus
|
Bolus, Purge,Anti-bolus,KVO
|
Obstruct pressure monitoring
|
DPS,13 levels occlusive detection
|
Syringe position detection
|
2 sensors: Plunger detection, flange detection
|
Alarm
|
Audible and visible Simulated display alarm reason (Unique) Female voice alarm system (Patent)
|
CPU
|
Dual microprocessor controlled
|
net weight
|
2.0kg
|
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |