Type: | Operation Apparatus |
---|---|
Syringe: | No |
Blood Sampling Needle: | No |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model: CCV-HB02
Features:
Veterinary Warming System utilizes the convection of air to transmit the hot air generated by the main unit o the through the pipeline, so that the heat energy is evenly distributed and transmitted to the blanket to achieve heat preservation or heating effect. For the prevention and treatment of hypothermia in small animals, it can accelerate the recovery of small animals and shorten the hospitalization time of small animals.
Multiple Wind Speed |
85adjustable wind speed can apply to different patients in different environments |
Multiple Temperature Control Protection |
Dual hardware and software temperature protection |
Multi-surface warming heat blanket |
Two types of material |
Air Purification Function |
plasma air purification function |
Reusable blankets size |
120cm x 60cm |
Noise |
During normal operation noise≤70dB(A) |
Item |
Specification |
Temperature Setting |
32.0 ~41.0°C,95.0 ~105.8°F |
Temperature Increment |
0.1°C, 0.1°F |
Temperature Deviation |
<±1°C, <±1.8°F |
Optional Unit |
°C & °F |
Warming Up Time |
≤4 minutes |
Working Mode |
Continuous working |
Operation Time |
Real time display |
Heating Blanket Mode |
Natural air mode and temperature control mode |
Operating time range |
00:00:00-99:59:59 Real-time display of operating time cleared after power off and on again |
Alarm |
Overheat,low temperature,no operation,fan error |
Display |
3.5-inch color LCD display |
Air Volume |
13.5m/s ~ 15.5m/s, 5 Level |
Air volume error |
±3m/s |
Quick Temperature Setting |
4 shortcut setting keys for 35°C, 37°C, 39°C, 41°C |
Alarm Volume |
3 Level |
Mute Time |
2 minutes |
Ambient Temperature Function |
Available |
Air Purification |
Plasma air purification |
Warming Heat Blanket |
Two types of material |
Temperature key-lock function |
Unable to change the temperature after startup operation |
Air duct |
Stretchable up to 3 meters |
Noise |
During normal operation noise≤70dB(A) |
Power Consumption |
1200VA |
Power supply |
AC220V, 50Hz/60Hz |
Type of Protection against Electric Shock |
Class I |
Degree of Protection against Electric Shock |
Applied part Type BF protection against defibrillation discharge effects |
Operation Environment |
Temp: +10°C~+40°C; Humidity: 30%~75%; Atmospheric pressure: non-condensation, 70KPa~106Kpa |
Storage Environment |
Temperature: -20°C~+55°C; Humidity: 10~93%; Atmospheric pressure: non-condensation, 50KPa~106Kpa |
Degree of Protection against Ingress of Liquid |
IPX2 |
Dimension |
260mm X 325mm X 325mm |
Weight |
7.5KG |
Overheat Protection Function |
Dual hardware and software protection, real-time temperature monitoring and over 50±5°C hardware forced power-off protection |
one-stop shopping hospital medical equipment |
x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) |
||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |